Magnetostrictive Guided Wave Monitoring Sensor
Category:
- Description
- Characteristics
- Configuration
-
Monitoring Distance < 120m Operating Temperature -40℃ to +120℃ Monitoring Sensitivity Minimum 3% cross-section loss change Battery Life Automatically wakes up once a day, can monitor for 3 years Protection Level Probe IP68, Host IP66/P68, the whole machine is waterproof and corrosion-resistant Applicable Pipe Diameter DN50-DN1200 -
► The use of permanent magnet design scheme, magnetic field stability, long-term use will not appear demagnetisation phenomenon;
► Acoustic energy 100% coverage of the pipeline cross-section, can detect defects in any position of the cross-section;
► Long propagation distance, suitable for large-scale equipment, long pipeline corrosion scanning and monitoring in a wide range of complex environments, such as pipelines with thermal insulation or anti-corrosion layer, buried pipelines, through the pipeline across;
► Long-distance ultrasonic guided wave monitoring sensor is fully self-developed and has unique patented technology;
► This product can monitor any elbow or straight section of the pipeline.
Tag: